Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cables telefónicos

 PE Insulated Air Core/Jelly Filled Paired Railway Signalling Cables (RF 0.3)

Solicitud

The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.

Normas

• RENFE E.T. 03.365.051.6

 

 

 

Construcción

Conductores
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228

Aislamiento
Solid polyethylene as per ASTM D 1248/IEC 60708

Pares trenzados
Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Cable Troncal Asamblea
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders

Núcleo de llenado (optional)
The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable

Envasado básico
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Barrera de humedad (optional)
An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap

Bedding
PE or LSZH

Pantalla electrostática
Corrugated copper tape of 0.12mm is applied longitudinally with overlap

Electrostática Armadura
Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one

Vaina
PVC or LSZH

Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Propiedades eléctricas

Nominal Conductor Diameter

mm

0.9

1.4

Conductor Size

mm2

0.636

1.539

Maximum Conductor Resistance @20°C

Ω/km

28

12.1

Minimum Insulation Resistance @500V DC

MΩ.km

35000

5000

Reduction Factor Rk (50Hz)  Induced Voltage Em 100V/Km

 

0.3

0.3

                                      Induced Voltage Em 500V/Km   0.5 0.5
Maximum Resistance Unbalance

%

2.5

2.5

Maximum Mutual Capacitance @0.8KHz

nF/km

59

64

Maximum Capacitance Unbalance @1KHz pair-to-pair

pF/500m

275

275

Maximum Capacitance Unbalance @1KHz pair-to-ground

pF/500m

1200

1200

Maximum Average Attenuation @1KHz

dB/km

0.7

0.46

Maximum Average Attenuation @10KHz

dB/km

1.6

0.85

Maximum Average Attenuation @20KHz

dB/km

2.1

1.3

Dielectric Strength Conductor to Conductor 1 min

V DC

1500

1500

                          Conductor to Screen 1min   V DC 2000 2000
Dielectric Strength Conductor to Conductor 3secs  V DC 3000 3000
                          Conductor to Screen 3secs   V DC 4500 4500
Nominal Insulation Thickness

mm

0.45

0.65

Nominal Insulated Conductor Diameter

mm

1.8

2.7

Propiedades mecánicas y térmicas

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter

Código de colores

Position Number of pairs
1(Pilot) 2(Direct) 3 4 5

Centre

BLACK

NATURAL

BLUE

NATURAL

YELLOW

NATURAL

RED

NATURAL

 

 

Layers

BLACK

NATURAL

BLUE

NATURAL

YELLOW

NATURAL

RED

NATURAL

GREEN

NATURAL

Dimensiones y peso

Código de cable

Número de pares

Nominal Bedding/ Grosor de la vaina mm

Diámetro nominal global
mm

Peso nominal kg/km

0.9mm Conductor, 1.8mm Insulated Wire
TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 2 1.5/1.6 18.3

1300

TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 6 1.5/1.6 21.7

1425

TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 10 1.5/1.6 25.2

1650

TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 14 1.5/1.6 26.7

1800

TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 20 1.5/1.6 29.2

2275

TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 28 1.6/1.8 32.3

2450

TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 38 1.7/1.8 36.0

2895

TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 54 1.7/1.8 40.5

3275

TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 74 1.8/2.0 45.6

3775

TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 96 1.9/2.0 49.8

4275

1.4mm Conductor, 2.7mm Insulated Wire
TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 2 1.5/1.6 20.2

1615

TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 6 1.5/1.6 25.7

1775

TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 10 1.6/1.8 30.8

2200

TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 14 1.6/1.8 32.8

2525

TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 20 1.7/1.8 36.5

2975

TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 28 1.7/1.8 40.5

3150

TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 38 1.8/2.0 45.6

3695

TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 58 2.0/2.2 52.3

3975

TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 74 2.1/2.2 59.1

4475

TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 96 2.2/2.3 66.0

4975