_clip_image002.jpg)
Solicitud
The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.
Normas
_clip_image002.gif)
• RENFE E.T. 03.365.051.6
Construcción
Conductores
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Aislamiento
Solid polyethylene as per ASTM D 1248/IEC 60708
Pares trenzados
Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk
Cable Troncal Asamblea
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
Núcleo de llenado (optional)
The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable
Envasado básico
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Barrera de humedad (optional)
An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap
Bedding
PE or LSZH
Pantalla electrostática
Corrugated copper tape of 0.12mm is applied longitudinally with overlap
Electrostática Armadura
Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
Vaina
PVC or LSZH
Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Propiedades eléctricas
Propiedades mecánicas y térmicas
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Código de colores
Position |
Number of pairs |
1(Pilot) |
2(Direct) |
3 |
4 |
5 |
Centre |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
|
|
Layers |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
GREEN |
NATURAL |
Dimensiones y peso
Código de cable |
Número de pares |
Nominal Bedding/ Grosor de la vaina mm |
Diámetro nominal global
mm |
Peso nominal kg/km |
0.9mm Conductor, 1.8mm Insulated Wire |
TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 |
2 |
1.5/1.6 |
18.3 |
1300 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 |
6 |
1.5/1.6 |
21.7 |
1425 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 |
10 |
1.5/1.6 |
25.2 |
1650 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 |
14 |
1.5/1.6 |
26.7 |
1800 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 |
20 |
1.5/1.6 |
29.2 |
2275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 |
28 |
1.6/1.8 |
32.3 |
2450 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 |
38 |
1.7/1.8 |
36.0 |
2895 |
TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 |
54 |
1.7/1.8 |
40.5 |
3275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 |
74 |
1.8/2.0 |
45.6 |
3775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 |
96 |
1.9/2.0 |
49.8 |
4275 |
1.4mm Conductor, 2.7mm Insulated Wire |
TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 |
2 |
1.5/1.6 |
20.2 |
1615 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 |
6 |
1.5/1.6 |
25.7 |
1775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 |
10 |
1.6/1.8 |
30.8 |
2200 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 |
14 |
1.6/1.8 |
32.8 |
2525 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 |
20 |
1.7/1.8 |
36.5 |
2975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 |
28 |
1.7/1.8 |
40.5 |
3150 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 |
38 |
1.8/2.0 |
45.6 |
3695 |
TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 |
58 |
2.0/2.2 |
52.3 |
3975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 |
74 |
2.1/2.2 |
59.1 |
4475 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 |
96 |
2.2/2.3 |
66.0 |
4975 |